Group 3 Electrical System - Hyundai HX145LCR Manual

Hide thumbs Also See for HX145LCR:
Table of Contents

Advertisement

GROUP 3 ELECTRICAL SYSTEM

GROUP 3 ELECTRICAL SYSTEM

1. WHEN STARTING SWITCH IS TURNED ON, MONITOR PANEL DISPLAY DOES NOT APPEAR
1. WHEN STARTING SWITCH IS TURNED ON, MONITOR PANEL DISPLAY DOES NOT APPEAR
·Before disconnecting the connector, always turn the starting switch OFF.
·Before carrying out below procedure, check all the related connectors are properly inserted and
short of fuse No. 7, 10.
·After checking, insert the disconnected connectors again immediately unless otherwise specified.
YES
Check voltage
between
CN-56A (2)
and (3)
Check voltage
Starting switch : ON
between CN-5
Voltage : 20~32V
NO
(9) and (10)
Starting switch : ON
Voltage : 20~32V
Check voltage
Check voltage
YES
20~32V
NO
0V
CLUSTER
BATT (24V)
POWER IG (24V)
GND
YES
NO
1
11
2
10
9
3
CN-56A
CN-5
6-24
Cause
Defective cluster
Replace
Disconnection in
Repair or replace
wiring harness or
(after clean)
poor contact
between
CN-5-CN-56A
Disconnection in
Repair or replace
wiring harness or
(after clean)
poor contact
between CN-5 (9)
-GND or fuse No.
7, 10
FUSE
12
NO.7
15
FUSE
CN-36-1
NO.10
Remedy
145LCR6ES01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents