Auto-Stop In Case Of Lower-Limit Frequency Continuous Operation - Toshiba TOSVERT VF-FS1 Instruction Manual

Industrial inverter for 3-phase induction motors
Hide thumbs Also See for TOSVERT VF-FS1:
Table of Contents

Advertisement

6.8
Auto-stop in case of lower-limit frequency continuous
operation
6.8.1
• Function
If operation is carried out continuously at a frequency command below the lower-limit frequency (
the period of time set with
time, "
This function will be canceled if a frequency command above the lower-limit frequency (
[Parameter setting]
6
Output frequency [Hz]
Operation signal (F or R)
Note: This function is enabled even at the start of operation and during switching between forward and
Auto-stop in case of lower-limit frequency continuous
operation

: Auto-stop in case of lower-limit frequency continuous operation

" is displayed (alternately) on the operation panel.
Title
Function
Auto-stop in case of lower-limit
frequency continuous operation time
+0.2Hz
reverse run.
, the inverter will automatically slow down the motor to a stop. At that
Adjustment range
0.0: Disabled
0.1-600.0 (s)
F-24
E6581381
) for
) +0.2Hz.
Default setting
0.0
Time [s]
ON