Toshiba TOSVERT VF-FS1 Instruction Manual page 147

Industrial inverter for 3-phase induction motors
Hide thumbs Also See for TOSVERT VF-FS1:
Table of Contents

Advertisement

3)
S-pattern acceleration/deceleration
Select this pattern to obtain
slow acceleration in a
demagnetizing region with a
small motor acceleration
torque. This pattern is
suitable for high-speed
spindle operation.
6.16.2 Switching acceleration/deceleration time 1 and 2
: Acceleration time 2
: Deceleration time 2
: Acceleration/deceleration 2 pattern
: Selecting an acceleration/deceleration pattern
: Acceleration/deceleration 1 and 2 switching frequency
• Function
Two acceleration times and two deceleration times can be specified individually. A method of selection or
switching can be selected from among the following:
1)
Selection by means of parameters
2)
Switching by changing frequencies
3)
Switching by means of terminals
Output frequency
[Hz]
Maximum frequency
Set frequency
Base frequency
0
Actual acceleration time
F-51
E6581381
Time [s]
6