6.4

Basic parameters 2

6.4.1
Switching motor characteristics via terminal input
: Base frequency 2
: Base frequency voltage 2
: Torque boost 2
: Motor electronic-thermal protection level 2
: Stall prevention level 2
• Function
Use the above parameters to switch the operation of two motors with a single inverter and to select
motor V/F characteristics (two types) according to the particular needs or operation mode.
Note: The
If motor 2 is selected, V/F control will be given constant torque characteristics.
[Parameter setting]
Title
Base frequency 2
Base frequency voltage 2
Torque boost 2
Motor electronic-thermal
protection level 2
Stall prevention level 2
(V/F control mode selection) parameter is enabled only for motor1.
Function
25.0-200.0 (Hz)
50-330 (V) : 200V class
50-660 (V) : 400V class
0.0-30.0 (%)
10-100 (%) / (A)
10-110 (%) / (A),
111 : Disabled
F-13
Adjustment range
50.0 (WP type)
60.0 (WN type)
Depending on model
E6581381
6
Default setting
230 (WP/WN type)
400 (WP type)
460(WN type)
( ⇒ See page K-14)
100
110

Advertisement

Table of Contents
loading

Table of Contents