Input Terminal Function - Toshiba TOSVERT VF-FS1 Instruction Manual

Industrial inverter for 3-phase induction motors
Hide thumbs Also See for TOSVERT VF-FS1:
Table of Contents

Advertisement

(2) A signal is sent out when either of the two functions assigned is activated.
Terminal
Title
symbol
RY - RC
RY - RC
RY - RC
Two different functions can be assigned to terminals RY-RC.
If parameter
activated.
Terminals RY-RC: Send out a signal when either of the functions set with
Timing chart
ON
OFF
ON
OFF
ON
RY-RC output
OFF
Only one function can be assigned to terminals FLA-FLB-FLC at a time.
(3) Holding the output of signals in ON status
If the conditions for activating the functions assigned to output terminals RY-RC agree with and as a result
the output of signals is put in ON status, the output of signals is held ON, even if the conditions change.
(Output terminal holding function)
Assign input terminal function 62 to a contact input terminal available.

Input terminal function

Function No.
Code
62
HDRY
Once output terminal RY-RC is turned on when the contact input terminal to which one of the above
functions (function 62) is assigned is ON, output terminal RY-RC is held ON.
Function
Output terminal selection 1A
Output terminal selection 1B
Output terminal logic selection
is set to
, a signal will be sent out when either of the two functions assigned is
Function
Holding of RY-RC terminal
output
F-11
Adjustment range
0 ~ 255
( ⇒ See page K-17)
255 (Always ON)
0 :
and
1 :
or
and
Action
ON: Once turned on, RY-RC is held on.
OFF: The status of RY-RC changes in real
time according to conditions.
E6581381
Default setting
4 (Low-speed
detection signal)
0
is activated.
6