Appendix 3
Input terminal function selection parameters
Table 8-3 is the function setting of 12 input terminals (including 4 virtual input terminals).
Table 8-4 is the input terminal functions.
Table 8-3 Input terminal function selection parameters
Communication
Title
No.
0104
f104
0108
f108
0110
f110
0111
f111
0112
f112
0113
f113
0114
f114
0115
f115
0116
f116
f117
0117
0118
f118
f151
0151
0152
f152
0153
f153
0154
f154
f155
0155
0156
f156
a973
A973
A974
a974
a975
A975
A976
a976
Note 1: For an explanation of the adjustment range, see Table 8-4 "Input terminal functions."
Function
Always active function selection 1
Always active function selection 2
Always active function selection 3
Input terminal selection 1A (F)
Input terminal selection 2A (R)
Input terminal selection 3A (RES)
Input terminal selection 4A (S1)
Input terminal selection 5 (S2)
Input terminal selection 6 (S3)
Input terminal selection 7 (VIB)
Input terminal function selection 8 (VIA)
Input terminal function selection 1B (F)
Input terminal function selection 2B (R)
Input terminal selection 3B (RES)
Input terminal selection 4B (S1)
Input terminal selection 1C (F)
Input terminal selection 2C (R)
Virtual input terminal selection 1
Virtual input terminal selection 2
Virtual input terminal selection 3
Virtual input terminal selection 4
- 29 -
E6581865
Adjustment
Default setting
range (Note 1)
0-153
0-153
0-153
0-203
0-203
0-203
0-203
10
0-203
12
0-203
14
0-203
16
8-55
24
0-203
0-203
0-203
0-203
0-203
0-203
0-203
0-203
0-203
0-203
0
0
6
2
4
8
0
0
0
0
0
0
0
0
0
0