Operate Pmcprimo Mc Hw2 - Show Hardware; Install Codesys - Pilz PMCprimo MC Operating Manual

Table of Contents

Advertisement

Commissioning
7.2.6

Operate PMCprimo MC HW2 - Show hardware

HW2 - Show Hardware State
0.1: HW2
0.1:
STATE OF DEVICES:
Device
------------------------------------------------------------------------------
PMCprimo MC
PMCtendo DD4
PMCprotego D
7.3

Install CODESYS

The development environment for programming in accordance with IEC 61131-3
CODESYS can be found in the software package "PMC Programming Tool". The software
package is available on the Internet at www.pilz.de.
After downloading
a Unpack the Zip file,
a Start the installation program.
The PMCprimo Target Package is installed.
Operating Manual PMCprimo MC
1003813-EN-03
Network
Addr
CH
---
---
---
CAN4
6
---
ECAT
51
---
FS
VN
---
03.05.00
---
5.180
---
6.22
State
ACTIVE
FAULT
ACTIVE