Pilz PMCprimo MC Operating Manual page 30

Table of Contents

Advertisement

Wiring
Connector X40a
Supply voltage 24 V
Connector X50a/
X50b
X50a
X50b
Supply voltage 24 V
Operating Manual PMCprimo MC
1003813-EN-03
Pin
Designation
1
+24 V
3
0 V supply
Supply voltage for:
the device, digital outputs X40b, interfaces
X42 to X45
and interfaces X51 and X52
X40a
1
3
*
Pin
Designation
1
+24 V
3
0 V supply
Supply voltage for
the two encoders X55 and X56
the digital outputs X50c
X50b
1
V+
3
X50a
1
V+
3
*
Description
Supply voltage +24 VDC
Earth for supply voltage
24 V connection isolated
from external power supply,
e.g. with isolating trans-
former
N
*If the link is removed, earth
fault monitoring must be
used in accordance with
EN 60204 / VDE 0113.
Description
Supply voltage +24 VDC
Reference earth for digital inputs
X50c
24 V connection isolated
from external power supply,
e.g. with isolating trans-
former
*If the link is removed, earth
fault monitoring must be
used in accordance with
EN 60204 / VDE 0113.
N
| 30