Operation
"Startup" operating status has been run without error. The system changes to "STOP"
status if no user program was loaded in "Startup" status.
1
The system changes to "Fatal Error" status if an error occurred in "Startup" status.
2
The system changes to "Startup" status if the "Boot Menu" in the terminal program is exited
using the command O or ESC.
3
The system performs a hardware reset after
Running the command RS1 in the terminal program (cold start).
}
Holding down the reset button for a long period (> 4 s) (alternative to RS1 command).
}
3
The system performs this status change after
Running the following commands in the terminal program:
}
– RS3 (change to "STOP")
– RS4 (warm reset), stops the user program
– RS5 (cold reset), stops the user program
– RS5 (original reset), deletes the user program
Running commands in the IEC 61131 development environment.
}
Holding down the reset button for a short period (< 4 s) (alternative to RS3 command,
}
change to "STOP").
3
The system changes to "Fatal Error" status if an error occurred in "RUN" status.
Remedy
Delete user program
}
Firmware update
}
4
The system performs a hardware reset after
Running the command RS1 in the terminal program (cold start).
}
Holding down the reset button for a long period (> 4 s) (alternative to RS1 command (cold
}
start)).
4
The system performs this status change after
Running the command RS2 in the terminal program (change to "RUN").
}
Running commands in the IEC 61131 development environment:
}
Operating Manual PMCprimo MC
1003813-EN-03
5
-->
Change from "Startup" to "Fatal Error"
1
-->
Change from "Boot Menu" to "Startup"
1
-->
Change from "RUN" to "Startup"
4
-->
Change from "RUN" to "STOP"
5
-->
Change from "RUN" to "Fatal Error"
1
-->
Change from "STOP" to "Startup"
3
Change from "STOP" to "RUN"
-->
| 58