To Output Ramp Signals

The parameters of Ramp waveform are: Frequency/Period, Start Phase,
Amplitude/High Level, Offset/Low Level, Symmetry.
To set the Frequency/Period, Start Phase, Amplitude/High Level, Offset/Low Level,
please refer to To Output Sine Signals on page 101.

To Set the Symmetry of Ramp

Select Symmetry in the right menu of Ramp. Set the parameter in the right menu.

To Output Pulse Signals

The parameters of Pulse waveform are: Frequency/Period, Start Phase,
Amplitude/High Level, Offset/Low Level, Width/Duty Cycle.
To set the Frequency/Period, Start Phase, Amplitude/High Level, Offset/Low Level,
please refer to To Output Sine Signals on page 101.

To Set the Pulse Width of Pulse

Select Width in the right menu (if Width is not displayed, select Duty Cycle and
select it again to switch to Width). Set the parameter in the right menu.

To Set the Duty Cycle of Pulse

Select Duty Cycle in the right menu (if Duty Cycle is not displayed, select Width
and select it again to switch to Duty Cycle). Set the parameter in the right menu.

To Output Arbitrary Signals

The menu items of Arbitrary waveform are: Frequency/Period, Start Phase,
Amplitude/High Level, Offset/Low Level, New, File Browse, Built-in. You can
operate the menu by using the menu selection buttons on the right.
To set the Frequency/Period, Start Phase, Amplitude/High Level, Offset/Low Level,
please refer to To Output Sine Signals on page 101.
The Arbitrary signal consists of two types: the user-definable waveform and the
system built-in waveform.

Create a New Waveform

(1) Enter the operation menu: Push
menu, select Others in the right menu, and select New.
(2) Set the number of waveform points: Select Points in the right menu, turn
the M knob to change the value, or use the input keyboard (push the M knob to
show it) to input the value and choose the unit. X1, X1000, Xle6, Xle9 in the
keyboard respectively represent 1, 1000, 1000000, 1000000000. The
waveform points range is 2 - 8192.
(3) Set the interpolation: Select Intrpl in the right menu, choose between On/Off.
If you choose On, the points will be connected with beelines; otherwise, the