voltages between two consecutive points will not change, and the waveform
looks like a step-up one.
(4) Edit the waveform points: Select Edit Points in the right menu.
Select Point, input the number of the point to be edited.
Select Voltage, input the voltage for the current point.
Repeat the step above, set all the points to your needs.
Select Save, enter the file system.
If you want to save the waveform to internal memory, select Memory in the
right menu as Internal. Turn the M knob to select a file from USER0 through
USER31. Select Save in the right menu.
If a USB device is connected, and you want to save the waveform to it, select
Memory in the right menu as USB. The instrument lists a directory of the
folders and files on the USB memory device. Select a folder or file using the M
knob to scroll up and down the list. To enter the current folder, select Change
Dir in the right menu, select it again to return to the upper directory.
Enter the desired storage path, select Save in the right menu, an input
keyboard pops up, input the file name, choose
The waveform is saved as BIN file in the folder.
Note: The input length can have up to 35 characters.
5.Use the Arbitrary Function Generator
104
Last modification time
File size
Waveform graph
in the keyboard to confirm .