[Pr. Pf89_Drive Recorder - Analog Channel Setting 3 (Drac3)]; [Pr. Pf90_Drive Recorder - Analog Channel Setting 4 (Drac4)] - Mitsubishi Electric MELSERVO-J5 MR-J5-G User Manual

Ac servo system
Hide thumbs Also See for MELSERVO-J5 MR-J5-G:
Table of Contents

Advertisement

[Pr. PF88.4-6_Drive recorder - Analog channel 4 selection]
Initial value
204h
Select the analog channel 4 of the drive recorder.
The servo parameter is disabled in the following conditions.
• [Pr. PF80.0 Drive recorder - Operation mode selection] is set to "0" (automatic setting mode)
Refer to the following for values that can be assigned.
Page 119 [Pr. PF87.0-2_Drive recorder - Analog channel 1 selection]

[Pr. PF89_Drive recorder - Analog channel setting 3 (DRAC3)]

Initial value
00090205h
[Pr. PF89.0-2_Drive recorder - Analog channel 5 selection]
Initial value
205h
Select the analog channel 5 of the drive recorder.
The servo parameter is disabled in the following conditions.
• [Pr. PF80.0 Drive recorder - Operation mode selection] is set to "0" (automatic setting mode)
Refer to the following for values that can be assigned.
Page 119 [Pr. PF87.0-2_Drive recorder - Analog channel 1 selection]
[Pr. PF89.4-6_Drive recorder - Analog channel 6 selection]
Initial value
009h
Select the analog channel 6 of the drive recorder.
The servo parameter is disabled in the following conditions.
• [Pr. PF80.0 Drive recorder - Operation mode selection] is set to "0" (automatic setting mode)
Refer to the following for values that can be assigned.
Page 119 [Pr. PF87.0-2_Drive recorder - Analog channel 1 selection]

[Pr. PF90_Drive recorder - Analog channel setting 4 (DRAC4)]

Initial value
0000000Ch
[Pr. PF90.0-2_Drive recorder - Analog channel 7 selection]
Initial value
00Ch
Select the analog channel 7 of the drive recorder.
The servo parameter is disabled in the following conditions.
• [Pr. PF80.0 Drive recorder - Operation mode selection] is set to "0" (automatic setting mode)
Refer to the following for values that can be assigned.
Page 119 [Pr. PF87.0-2_Drive recorder - Analog channel 1 selection]
Setting range
Refer to the text
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
Setting range
Refer to the text
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
Ver.
A0
Setting method
Each axis
Ver.
A0
Ver.
A0
Setting method
Each axis
Ver.
A0
1 SERVO PARAMETER DETAILS
1.7 Extension setting 3 servo parameters group ([Pr. PF_ _ ])
Ver.
Refer to the relevant detail No.
Ver.
Refer to the relevant detail No.
121
1