[Pr. Psd12_Input Device - Noise Elimination Filter Time Di1 (**Sdif1)] - Mitsubishi Electric MELSERVO-J5 MR-J5-G User Manual

Ac servo system
Hide thumbs Also See for MELSERVO-J5 MR-J5-G:
Table of Contents

Advertisement

[Pr. PSD08.3_Output axis selection DO1]
Initial value
0h
0: All axes
1: A-axis
2: B-axis
3: C-axis
If the setting value is 1, the device name is _ _ _-A. (example: "STOS-A")
If the setting value is 2, the device name is _ _ _-B. (example: "STOS-B")
If the setting value is 3, the device name is _ _ _-C. (example: "STOS-C")
[Pr. PSD12_Input device - Noise elimination filter time DI1
(**SDIF1)]
Initial value
00000001h
Select the filter time to use for reducing noise from the input signal of the CN8-4/CN8-5 pin.
Refer to the following table for details.
Configuration
The switch is used.
A machine utilizing the diagnosis function is used.
[Pr. PSD12.0-1_Noise elimination filter time DI1]
Initial value
01h
Select the filter time for the input signal of the CN8-4/CN8-5 pin.
Refer to the following table for setting values.
Setting value
00
01
02
03
04
05
Setting range
Refer to the text
Setting range
Refer to the relevant detail No.
Test pulses are in superposition in the output signal
of the device.
Test pulses are not in superposition in the output
signal of the device.
Setting range
Refer to the text
Filtering time [ms]
1.000
2.000
4.000
8.000
16.000
32.000
Ver.
B2
Setting method
Common
Noise elimination filter time
Set 1.00 ms or more.
Set a time that is at least 1.00 ms longer than the
off time for test pulses outputted by the machine.
Set 1.00 ms or more.
Ver.
B2
7 FUNCTIONAL SAFETY PARAMETER DETAILS
7.4 Safety I/O device parameters group ([Pr. PSD_ _ ])
Ver.
Refer to the relevant detail No.
205