[Pr. Pb32_Speed Integral Compensation After Gain Switching (Vicb)]; [Pr. Pb33_Vibration Suppression Control 1 - Vibration Frequency After Gain Switching (Vrf11B)]; [Pr. Pb34_Vibration Suppression Control 1 - Resonance Frequency After Gain Switching (Vrf12B)]; [Pr. Pb35_Vibration Suppression Control 1 - Vibration Frequency Damping After Gain Switching (Vrf13B)] - Mitsubishi Electric MELSERVO-J5 MR-J5-G User Manual

Ac servo system
Hide thumbs Also See for MELSERVO-J5 MR-J5-G:
Table of Contents

Advertisement

[Pr. PB32_Speed integral compensation after gain switching
(VICB)]
Initial value
0.0 [ms]
Set the speed integral compensation for when the gain switching is enabled.
When the setting value of this servo parameter is less than "0.1", the setting value of [Pr. PB10 Speed integral compensation]
is applied.
The setting value of this servo parameter is enabled when [Pr. PA08.0 Gain adjustment mode selection] is set to "3" (manual
mode).
[Pr. PB33_Vibration suppression control 1 - Vibration frequency
after gain switching (VRF11B)]
Initial value
0.0 [Hz]
Set the vibration frequency of vibration suppression control 1 for when the gain switching is enabled.
When the setting value of this servo parameter is less than "0.1", the setting value of [Pr. PB19 Vibration suppression control
1 - Vibration frequency] is applied.
This servo parameter is enabled in the following conditions:
• [Pr. PA08.0 Gain adjustment mode selection] is set to "3" (manual mode).
• [Pr. PB02.0 Vibration suppression control 1 - Tuning mode selection] is set to "2" (manual setting).
• "1" (signal (CDP/C_CDP)) is selected in [Pr. PB26.0 Gain switching selection].
Switching gains during driving may cause a shock. Switch the gains after the servo motor has stopped.
[Pr. PB34_Vibration suppression control 1 - Resonance
frequency after gain switching (VRF12B)]
Initial value
0.0 [Hz]
Set the resonance frequency for vibration suppression control 1 for when the gain switching is enabled.
When the setting value of this servo parameter is less than "0.1", the setting value of [Pr. PB20 Vibration suppression control
1 - Resonance frequency] is applied.
This servo parameter is enabled in the following conditions:
• [Pr. PA08.0 Gain adjustment mode selection] is set to "3" (manual mode).
• [Pr. PB02.0 Vibration suppression control 1 - Tuning mode selection] is set to "2" (manual setting).
• "1" (signal (CDP/C_CDP)) is selected in [Pr. PB26.0 Gain switching selection].
Switching gains during driving may cause a shock. Switch the gains after the servo motor has stopped.
[Pr. PB35_Vibration suppression control 1 - Vibration frequency
damping after gain switching (VRF13B)]
Initial value
0.00
Set the damping of the vibration frequency for vibration suppression control 1 for when the gain switching is enabled.
This servo parameter is enabled in the following conditions:
• [Pr. PA08.0 Gain adjustment mode selection] is set to "3" (manual mode).
• [Pr. PB02.0 Vibration suppression control 1 - Tuning mode selection] is set to "2" (manual setting).
• "1" (signal (CDP/C_CDP)) is selected in [Pr. PB26.0 Gain switching selection].
Switching gains during driving may cause a shock. Switch the gains after the servo motor has stopped.
Setting range
0.0 to 5000.0
Setting range
0.0 to 300.0
Setting range
0.0 to 300.0
Setting range
0.00 to 0.30
Setting method
Each axis
Setting method
Each axis
Setting method
Each axis
Setting method
Each axis
1 SERVO PARAMETER DETAILS
1.3 Gain/filter setting servo parameters group ([Pr. PB_ _ ])
Ver.
A0
Ver.
A0
Ver.
A0
Ver.
A0
1
47

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo-j5 mr-j5w-g

Table of Contents