Mitsubishi Electric MELSERVO-J5 MR-J5-G User Manual page 117

Ac servo system
Hide thumbs Also See for MELSERVO-J5 MR-J5-G:
Table of Contents

Advertisement

[Pr. PF82.1_Drive recorder - Trigger binding condition selection]
Initial value
0h
Select the trigger binding condition for the drive recorder.
When this servo parameter is set to "0" (disabled), the settings of [PF84.2-3 Drive recorder - Trigger channel selection 2] and
[PF86 Drive recorder - Trigger level setting 2] are disabled.
When [Pr. PF80.0 Drive recorder - Operation mode selection] is set to "0" (automatic setting mode), or [Pr. PF80.0] is set to
"1" and [Pr. PF82.0 Drive recorder - Trigger mode selection] is set to "0" (alarm trigger), the setting value of this servo
parameter is disabled.
0: Disabled
1: Logical AND of trigger signals
2: Logical OR of trigger signals
[Pr. PF82.2_Drive recorder - Trigger operation selection 1]
Initial value
0h
Select whether sampling starts when the signal output for the drive recorder channel set in [Pr. PF84.0-1 Drive recorder -
Trigger channel selection 1] exceeds or falls below the set trigger level.
When [Pr. PF80.0 Drive recorder - Operation mode selection] is set to "0" (automatic setting mode), or [Pr. PF80.0] is set to
"1" and [Pr. PF82.0] is set to "0", the setting value of this servo parameter is disabled.
0: Rising
1: Falling
[Pr. PF82.3_Drive recorder - Trigger operation selection 2]
Initial value
0h
Select whether sampling starts when the signal output for the drive recorder channel set in [Pr. PF84.2-3 Drive recorder -
Trigger channel selection 2] exceeds or falls below the set trigger level.
The servo parameter is disabled in the following conditions.
• [Pr. PF80.0 Drive recorder - Operation mode selection] is set to "0" (automatic setting mode)
• [Pr. PF82.0 Drive recorder - Trigger mode selection] is set to "0" (alarm trigger)
• [Pr. PF82.1 Drive recorder - Trigger binding condition selection] is set to "0" (disabled)
0: Rising
1: Falling
Setting range
Refer to the text
Setting range
Refer to the text
Setting range
Refer to the text
1.7 Extension setting 3 servo parameters group ([Pr. PF_ _ ])
Ver.
A0
Ver.
A0
Ver.
A0
1 SERVO PARAMETER DETAILS
1
115

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo-j5 mr-j5w-g