[Pr. Pe10_Fully Closed Loop Function Selection 3 (Fct3)]; [Pr. Pe41_Function Selection E-3 (Eop3)]; [Pr. Pe44_Lost Motion Compensation Positive-Side Compensation Value Selection (Lmcp)]; [Pr. Pe45_Lost Motion Compensation Negative-Side Compensation Value Selection (Lmcn)] - Mitsubishi Electric MELSERVO-J5 MR-J5-G User Manual

Ac servo system
Hide thumbs Also See for MELSERVO-J5 MR-J5-G:
Table of Contents

Advertisement

[Pr. PE10_Fully closed loop function selection 3 (FCT3)]

Initial value
00000000h
[Pr. PE10.1_Fully closed loop control - Position deviation error detection level - Unit
selection]
Initial value
0h
0: 1 kpulse unit
1: 1 pulse unit

[Pr. PE41_Function selection E-3 (EOP3)]

Initial value
00000000h
[Pr. PE41.0_Robust filter selection]
Initial value
0h
0: Disabled
1: Enabled
When this setting value is set to "Enabled", the machine resonance suppression filter 5 set in [Pr. PB51 Notch shape selection
5] cannot be used.
[Pr. PE41.6_Unbalanced torque offset setting selection]
Initial value
0h
0: Manual setting
1: Automatic setting
If "1" (automatic setting) has been set and friction estimation by the machine diagnosis function has completed for both the
forward and reverse rotations, the value of [Pr. PE47 Unbalanced torque offset] will be set automatically according to the
estimated friction value. After [Pr. PE47] is set automatically, this servo parameter changes to "0" (Manual setting). Until
friction estimation completes for both the forward and reverse rotations, this servo parameter keeps the value "1" (automatic
setting) and the value of [Pr. PE47] will not be set automatically.
[Pr. PE44_Lost motion compensation positive-side compensation
value selection (LMCP)]
Initial value
0 [0.01 %]
Set the lost motion compensation for when negative speed switches to positive speed in increments of 0.01 % in relation to
the rated torque as 100 %.
[Pr. PE45_Lost motion compensation negative-side
compensation value selection (LMCN)]
Initial value
0 [0.01 %]
Set the lost motion compensation for when positive speed switches to negative speed in increments of 0.01 % in relation to
the rated torque as 100 %.
1 SERVO PARAMETER DETAILS
98
1.6 Extension setting 2 servo parameters group ([Pr. PE_ _ ])
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
Setting range
Refer to the text
Setting range
0 to 30000
Setting range
0 to 30000
Setting method
Each axis
Ver.
A5
Setting method
Each axis
Ver.
A0
Ver.
A0
Setting method
Each axis
Setting method
Each axis
Ver.
Refer to the relevant detail No.
Ver.
Refer to the relevant detail No.
Ver.
A0
Ver.
A0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo-j5 mr-j5w-g

Table of Contents