Enterasys SmartSwitch 6000 User Manual page 59

Local management
Hide thumbs Also See for SmartSwitch 6000:
Table of Contents

Advertisement

The access level can be set to one of the following levels for each user name:
• super-user
• read-write
• read-only
To support multiple access levels per user name, it involves sending back a different "FilterID"
attribute using some server feature to differentiate between the same user name with different
prefixes/suffixes. For example, "username@engineering" and "username@home" could each
return different access levels.
NOTE: This is a server-dependent feature.
A Radius user/password combination is assigned one access level unless server-specific features
such as prefixes or suffixes are used to assign different access levels.
All radius values, except the server IPs and shared secrets, are assigned reasonable default values
when radius is installed on a new switch module. The defaults are as follows:
• Client, disabled
• Timeout, 20 seconds
• Retries, 3
• Primary and secondary Authentication ports: 1812 (per RFC 2865)
• Primary and secondary Accounting ports: 1813 (per RFC 2866)
• Last-resort for local and remote is CHALLENGE
If only one server is configured, it must be the primary server. It is not necessary to reboot after the
client is reconfigured.
The client cannot be enabled unless the primary server is configured with at least the minimum
configuration information.
NOTE: The minimum additional information that must be configured to use a server is
its IP and Shared Secret.
Overview of Security Methods
Accessing Local Management
3-17

Hide quick links:

Advertisement

Table of Contents
loading