Buselan - Cabletron Systems SmartCell 6A000 Reference Manual

Enterasys smartcell 6a000: reference guide atm switch
Hide thumbs Also See for SmartCell 6A000:
Table of Contents

Advertisement

Console Commands

BUSELAN

Use BUSELAN (broadcast and unknown server emulated LAN) to determine the characteristics of the specified
ELAN maintained by the BUS. If the corresponding LESELAN exists, it should be identical.
Operators
add, delete, modify, show
Parameters
Input Parameter
[ELANNumber]
[ELANName]
[ConnectMethod]
[ELANType]
[Multipoint]
[MTU]
Output Parameter
[ATM Address]
[Distribute VPI/VCI]
Description
Number of the ELAN to which the BUS
belongs.
Name of the ELAN to which the BUS belongs. Up to 32 characters
Type of connection used.
Data-link type used by the ELAN.
Indicates whether control distribute VCC is
PMP (point-to-multipoint) or PTP
(point-to-point).
Maximum transfer unit assigned for this client. 1516 or 9234 (Ethernet),
Description
ATM address of the ELAN.
VPI/VCI values of control direct VCC or multicast send VCC.
Value/Field Size
0-127, ALL
PVC, SVC
802.3 (Ethernet),
802.5 (TokenRing)
YES: VCC is PMP
NO: VCC is PTP
4544 (Token Ring)
SmartCell 6A000/ZX-250 Reference Manual 2-13
Default
0 for add ,
delete , and
modify
operators;
ALL for
show
operator
ELAN000
SVC
802.3
YES
1516