LECSTLVSet

Use LECSTLVSet (LAN emulation configuration server type, length, and value set) to manipulate TLV parameters on
the LECS. A TLV set is a collection of TLV parameters associated with an ELAN (emulated LAN).
Operators
add, delete, modify, show
Parameters
Parameter
[TLVSetNumber]
[ControlTimeout]
[MaxUnknownFrameCount]
[MaxUnknownFrameTime]
[VCCTimeout]
[MaxRetryCount]
[ArpAgingTime]
[ForwardDelay]
[ArpResponseTime]
2-84 SmartCell 6A000/ZX-250 Reference Manual
Description
Number that identifies the set of TLV
parameters on the LECS.
Time-out period used for timing out most
request/response control-frame
interactions.
Total counter frames a LANE client will
send to the LECS for a given unicast LAN
destination.
Total time frames a LANE client will send
the LECS for a given unicast LAN
destination.
Time-out period for releasing a data direct
VCC on an LEC if it has not been used to
transmit or receive any data.
Maximum number of times a LEC should
try for a given LAN destination.
Maximum time that a LEC maintains an
entry in its cache in the absence of updates.
Maximum time a LEC will maintain an
entry for a non-local MAC address in its
cache in the absence of updates.
Maximum time that the LEC expects a
request/response cycle to take.
Console Commands
Value/Field Size
Default
1-32767
1
seconds/10-300
n/a
1-10
n/a
seconds/1-160
n/a
seconds/0-65535
n/a
0-2
n/a
seconds/10-300
n/a
seconds/4--30
n/a
seconds/1-30
n/a