Figure 11-13. Example of 1-Trigger Mode (Timer Trigger Scan 1-Trigger) Operation
INTCC110
(1)
CE bit of ADM0 is set to 1 (enable)
(2)
CC110 compare generation
(3)
ANI0 A/D conversion
(4)
Conversion result is stored in ADCR0
(5)
CC110 compare generation
(6)
ANI1 A/D conversion
(7)
Conversion result is stored in ADCR1
Caution The analog input enclosed in the broken lines cannot be used with INTCC11n as the trigger (n
= 0 to 3). When a setting is made to scan ANI0 to ANI7, ANI4 to ANI7 are converted in A/D
trigger mode (see (b)).
INTCC110
(1) to (13) Same as (a)
(14) ANI4 A/D conversion
(15) Conversion result is stored in ADCR4
(16) ANI5 A/D conversion
(17) Conversion result is stored in ADCR5
338
CHAPTER 11 A/D CONVERTER
(a) Setting when scanning ANI0 to ANI3
ANI0
ANI1
ANI2
ANI3
A/D converter
ANI4
ANI5
ANI6
ANI7
(8)
(9)
(10) Conversion result is stored in ADCR2
(11) CC110 compare generation
(12) ANI3 A/D conversion
(13) Conversion result is stored in ADCR3
(14) INTAD interrupt generation
(b) Setting when scanning ANI0 to ANI7
ANI0
ANI1
ANI2
ANI3
A/D converter
ANI4
ANI5
ANI6
ANI7
(18) ANI6 A/D conversion
(19) Conversion result is stored in ADCR6
(20) ANI7 A/D conversion
(21) Conversion result is stored in ADCR7
(22) INTAD interrupt generation
User's Manual U12688EJ4V0UM00
CC110 compare generation
ANI2 A/D conversion
ADCR0
ADCR1
ADCR2
ADCR3
ADCR4
ADCR5
ADCR6
ADCR7
ADCR0
ADCR1
ADCR2
ADCR3
ADCR4
ADCR5
ADCR6
ADCR7