M800W/M80W Series Connection and Setup Manual
11 Connection of Operation Panel I/O Unit
11.10 Connecting with Manual Pulse Generator (MPG)
Connect the manual pulse generator to MPG connector of the operation panel I/O unit.
Both 5V power supply type (UFO-01-2Z9) and 12V power supply type (HD60C) manual pulse generator can be used.
Take the maximum cable length, etc. into consideration when selecting.
(Note)
Set one of the following parameters which is suitable for your manual pulse generator.
- 5V manual pulse generator (UFO-01-2Z9) : #1240 set12/bit0 = 1 (100 pulse/rev)
-12V manual pulse generator (HD60C)
(1) Connecting with 5V manual pulse generator (maximum cable length: 20m)
Connect the 5V manual pulse generator to the connector MPG.
Operation panel
I/O unit
MPG
: #1240 set12/bit0 = 0 ( 25 pulse/rev)
When connecting one 5V
manual pulse generator
J023
When connecting two 5V
manual pulse generators
J024
When connecting three
5V manual pulse
generators
J025
299
NO.1
5V 0V A B
NO.2
NO.1
5V 0V A B
5V 0V A B
NO.3
NO.2
5V 0V A B
5V 0V A B
5V manual pulse
generator
(Rear view)
NO.1
5V 0V A B
IB-1501268-K