Mitsubishi Electric M800W Series Connection And Set Up Manual page 400

Hide thumbs Also See for M800W Series:
Table of Contents

Advertisement

M800W/M80W Series Connection and Setup Manual
16 Connection of Machine Operation Panel
<Wiring of other switches (SUBP)>
EMG
(Note 1) Wirings for memory protection switches must be directly soldered to terminals or use tab
(Note 2) When wiring the emergency stop switch, the crimp terminal must be fastened with thread.
(Note 3) For NCs whose control unit and display unit are integrated, wire the emergency stop switch
(Note 4) Select a rotary switch which guarantees 5V/1mA.
(Note 5) Length of cables must be 0.5m or shorter.
(Note 6) The numbers in the above diagram do not indicate the actual device numbers.
Main panel A/B (FCU8-KB92x)
+5V
R
X72
R
X73
R
X74
R
X75
[EXT]
A01
B01
A02
B02
A03
B03
A04
B04
A05
B05
terminals (110 series).
directly to the EMG connector of the control unit. (Use J121 cable)
For a separated-type NC, wire it directly to the EMG connector of the operation panel I/O unit.
[SUBP]
Sub panel A (FCU8-KB931/KB941)
A13
B13
A14
B14
A15
Switch input spare
B15
(3 points)
A16
B16
A17
B17
A18
Spare for signal relay
B18
A19
B19
A20
B20
361
Memory protection switch
2 notch Key shape
2c Manual return type
Push down switch
(For emergency stop)
Push Lock -
Turn Reset
2a2b contact
IB-1501268-K

Advertisement

Table of Contents
loading

This manual is also suitable for:

M80w seriesM850wM830wM80w

Table of Contents