M800W/M80W Series Connection and Setup Manual
20 Setting the Hardware

20.6.3 Station No. Setting when Using Multiple Remote I/O Units

Multiple remote I/O units can be used, as long as the total No. of occupied stations connected with serial links is
eight or less. (four/five or less when connected to the operation panel I/O unit).
When using multiple remote I/O units, a characteristic station No. must be set for each unit. A unit has the station
No. group setting switches and the station No. setting switch. These switches must be set to the characteristic
station No. which is not duplicate with the occupied stations of the operation panel I/O unit.
(Note 1) The maximum connectable number of remote I/O units is 32 per channel.
(Note 2) Only one FCU8-DX408 unit can be connected in the entire system.
(Note 3) The maximum connectable number of FCU8-DX409 is four.
When connecting directly to the control unit
Setting example 1
Control unit
Unit type
FCU8-DX220
FCU8-DX230
FCU8-DX231
FCU8-DX202
FCU8-DX213/DX213-1
FCU8-DX654/DX654-1
FCU8-DX651
FCU8-DX408 (Note 2)
FCU8-DX409 (Note 3)
Remote I/O unit
FCU8-DX213, FCU8-DX213-1, FCU8-DX220
0
1
2
8
9
A
0
1
2
8
9
A
Number of occupied stations
1
2
2
1
1
2
3
3
4
3
4
5
6
B
C
D
E
3
4
5
B
C
D
E
427
Group1
1:OFF
2:OFF
7
Group1
1:OFF
2:OFF
F
Group2
1:OFF
2:ON
6
7
Group2
1:OFF
2:ON
F
IB-1501268-K