Mitsubishi Electric M800W Series Connection And Set Up Manual page 75

Hide thumbs Also See for M800W Series:
Table of Contents

Advertisement

M800W/M80W Series Connection and Setup Manual
4 General Specifications
(4) GDI (Ethernet communication for personal computer unit connection)
1
8
1
O
TXD+
2
O
TXD-
3
I
RXD+
4
NC
5
NC
6
I
RXD-
7
NC
8
NC
- Connect connector case with FG pattern.
- Use J303 cable when directly connecting a device such as a personal computer to the unit.
<Cable side connector type>
Connector : J00026A0165
Manufacturer: Japan Telegärtner
(5) SIO (RS-232C communication 2ch)
10
20
1
0V
2
I
RD1(RXD1)
3
I
CS1(CTS1)
4
I
DR1(DSR1)
5
0V
6
NC
7
I
RD2(RXD2)
8
I
CS2(CTS2)
9
I
DR2(DSR2)
10
NC
- Connect connector case with FG pattern.
<Cable side connector type>
Plug : 10120-3000PE
Shell : 10320-52F0-008
Manufacturer: 3M
(Note)
IB-1501268-K
1
11
11
0V
12
O
SD1(TXD1)
13
O
RS1(RTS1)
14
O
ER1(DTR1)
15
0V
16
NC
17
O
SD2(TXD2)
18
O
RS2(RTS2)
19
O
ER2(DTR2)
20
NC
When using the jackscrew M2.6-type 10320-52A0-008 for the shell, do not fasten the screws
too tightly otherwise the connector and the PCB may be damaged.
(Manufacturer recommended tightening torque: 0.20±0.05Nꞏm)