4 General Specifications
(15) AIO (Analog input 4ch, Analog output 2ch, 5V Manual pulse generator input 2ch)
Analog input, analog output and 5V manual pulse generator can be connected to this connector.
10
20
1
0V
2
I
AI 0
3
I
AI 2
4
0V
5
0V
6
O
AO 0
7
I
HA2_A
8
I
HA1_A
9
0V
10
O
+5V
- Connect connector case with FG pattern.
<Cable side connector type>
Plug : 10120-3000PE
Shell : 10320-52F0-008
Manufacturer: 3M
(Note)
IB-1501268-K
1
11
11
0V
12
I
AI 1
13
I
AI 3
14
0V
15
0V
16
O
AO 1
17
I
HA2_B
18
I
HA1_B
19
0V
20
O
+5V
When using the jackscrew M2.6-type 10320-52A0-008 for the shell, do not fasten the screws
too tightly otherwise the connector and the PCB may be damaged.
(Manufacturer recommended tightening torque: 0.20±0.05Nꞏm)