M800W/M80W Series Connection and Setup Manual
39 Appx.2: Protection Setting
Display items
Automatic backup (Output)
Batch backups (menu [Backup])
Batch backups (menu [Master Backup])
Batch backups (menu [Restore])
Batch backups (menu [Master Restore])
HMI environment setting
Memory format
All erasure of machining programs
All erasure of machine macros
All erasure of life data
All erasure of tool data
fixpro formatting
HMI version-up
System version-up
Setup parameter
Console execution
data
Ladder monitoring (Note 1)
Machine tool builder macro variables
WE measurement macro writing
Machine tool builder macro ROM write
Security function
SRAM data files (SRAM.BIN)
User PLC program files (USERPLC.LAD)
User PLC program files per project
(PROJECTxx.: 01 to available project No.)
APLC data file (APLC.BIN)
Custom folder (MSYS\CUSTOM)
EtherNet/IP configuration file (EIPCONFDATA.BIN)
Machine tool builder macro variables data file
(MMACRO.VAR)
Program editing (only for memory)
Buffer correction (only for memory)
Program editing
Machining program files (PRG/USER)
Fixed cycle program (PRG/FIX)
Common variable data (Note 3)
Common variable
data
Common variable data files (COMMON.VAR)
Origin set operation G92 set
Operator mail notification setting
Email communication address file
Email communication setting file
Operator mail
notification data
Email communication log file on input/output screen
Email communication address file
Email communication setting file
(Note 1) When the protection level set for "Chng" of "Setup parameter data" is any of 0 to 3, if all the following
conditions are met, PLC on-board can be started but it cannot be edited.
- Operation level is "3" or lower
- Operation level is at the protection level or higher
(Note 2) When the set protection level for "Out." of "Program edit" is higher than the current operation level, any
program cannot be opened on the Edit screen. The message "Data protect" appears.
(Note 3) The common variables protected in #12111 to #12114 cannot be configured or changed regardless of the
operation level or the protection level.
(Note 4) For specifications on inputting and outputting files which are objects to be protected, refer to "Instruction
Manual".
IB-1501268-K
Objects to be protected
620
Initial value
Change Output Change Output Change Output
-
-
6
(Note 2)
0
-
0
-
0
-
0
-
Setting range
0
0-6
0-6
0
0-6
0-6
0
0-6
0-6
0
0-6
0-6
0
0-6
0-6