M800W/M80W Series Connection and Setup Manual
4 General Specifications
CAUTION
Do not apply any voltage to the connectors other than voltage specified in this manual. Failure to observe this
could cause bursting, damage, etc.
Connect the cables to the designated connectors. Incorrect connections could damage the device.
12V, 5V, and 3.3V output from connectors are to supply the power for dedicated peripheral devices. Do not
use for other equipment to supply the power since we do not guarantee the NC operation by voltage down or
noise sneaking.
(1) CG31 (Machine signal input)
Digital input 32 points (1st station)
(3) CG33 (Machine signal input)
Digital input 32 points (2nd station)
B1
A1
B
20
I
X200
19
I
X201
18
I
X202
17
I
X203
16
I
X204
15
I
X205
14
I
X206
13
I
X207
12
I
X208
11
I
X209
10
I
X20A
9
I
X20B
8
I
X20C
7
I
X20D
6
I
X20E
5
I
X20F
4
NC
3
DICOM
2
+24V
1
+24V
The input/output assignment is modifiable using a parameter. Refer to "20.6.4.2 Arbitrary Device Assignment"
for details.
<Cable side connector type>
Connector : XG4M-4030 / 7940-6500SC
Strain relief : XG4T-4004 / 3448-7940
Manufacturer: OMRON / 3M
IB-1501268-K
B20
A20
CG31
A
20
I
X210
19
I
X211
18
I
X212
17
I
X213
16
I
X214
15
I
X215
14
I
X216
13
I
X217
12
I
X218
11
I
X219
10
I
X21A
9
I
X21B
8
I
X21C
7
I
X21D
6
I
X21E
5
I
X21F
4
NC
3
DICOM
2
0V
1
0V
102
CG33
B
A
20
I
X220
20
I
19
I
X221
19
I
18
I
X222
18
I
17
I
X223
17
I
16
I
X224
16
I
15
I
X225
15
I
14
I
X226
14
I
13
I
X227
13
I
12
I
X228
12
I
11
I
X229
11
I
10
I
X22A
10
I
9
I
X22B
9
I
8
I
X22C
8
I
7
I
X22D
7
I
6
I
X22E
6
I
5
I
X22F
5
I
4
NC
4
3
DICOM
3
2
+24V
2
1
+24V
1
X230
X231
X232
X233
X234
X235
X236
X237
X238
X239
X23A
X23B
X23C
X23D
X23E
X23F
NC
DICOM
0V
0V