23 Sequence Program Writing

23.4 Setting the Communication with GX Developer

To create the machine sequence and user safety sequence of the CNC, use the Mitsubishi integrated FA software GX
Developer, which is the PLC development tool for the Mitsubishi PLC MELSEC Series.
Machine sequence:
User safety sequence:
When using GX Works2, refer to "Setting the Communication with GX Works2".
(1) Perform the following operations with GX Developer to start the setup screen.
[Online] -> [Transfer setup...]
(2) Set the following items in order.
(a) For the machine sequence
PC side I/F
Network No.
Station No.
Protocol
PLC side I/F
Type name
Station No.
IP address
Routing parameter conversion method
Other station
Time out check (sec.)
Number of retry
Network communication path
Access to the Ethernet unit that is set with PLC side I/F
*1: The setting items are displayed by double-clicking the Ethernet board selection field.
*2: The setting items are displayed by double-clicking the Ethernet unit selection field.
*3: The setting items are displayed by double-clicking the other station (Single network) selection field.
*4: The setting items are displayed by double-clicking the Ethernet unit selection field.
■ SW8D5C-GPPW setting screen
Control circuit created to control the machine tools (ladder circuit)
Control circuit of the safety-related I/O observation created with the smart safety observation
function (ladder circuit)
Setting item
Ethernet board
1
1
TCP
Ethernet unit
QJ71E71
1
IP address of CNC
Automatic conversion method
Other station (Single network)
Arbitrary time (from about 10 sec.)
0
Ethernet
Setting content
457
Remark
*1
*1
*1
*2
*2
*2
*2
*3
*3
*4
IB-1501268-K