M800W/M80W Series Connection and Setup Manual
4 General Specifications
(13) LAN1 (Ethernet communication)
1
8
1
I/O
TXRXD0+
2
I/O
TXRXD0-
3
I/O
TXRXD1+
4
I/O
TXRXD2+
5
I/O
TXRXD2-
6
I/O
TXRXD1-
7
I/O
TXRXD3+
8
I/O
TXRXD3-
- Connect connector case with FG pattern.
- Use J303 cable when directly connecting a device such as a personal computer to the unit.
<Cable side connector type>
Connector : J00026A0165
Manufacturer: Japan Telegärtner
(14) LAN2 (Ethernet communication)
1
8
1
I/O
RD-
2
I/O
RD+
3
I/O
TD-
4
I/O
TCT
5
I/O
TCT
6
I/O
TD+
7
I/O
RCT
8
I/O
RCT
- Connect connector case with FG pattern.
- Use J303 cable when directly connecting a device such as a personal computer to the unit.
<Cable side connector type>
Connector : J00026A0165
Manufacturer: Japan Telegärtner
(15) FG (FG terminal)
(16) LCD (Display unit signal I/F)
(17) TP (Touch panel I/F)
IB-1501268-K
86