4.3.3 Connecting with Manual Pulse Generator (MPG)

Both 5V power supply type (UFO-01-2Z9) and 12V power supply type (HD60C) manual pulse generator can be used.
Take the maximum cable length, etc. into consideration when selecting.
(Note)
Set one of the following parameters which is suitable for your manual pulse generator.
- 5V manual pulse generator (UFO-01-2Z9) : #1240 set12/bit0 = 1 (100 pulse/rev)
-12V manual pulse generator (HD60C)
(1) Connecting with 5V manual pulse generator (maximum cable length: 20m)
Connect the 5V manual pulse generator to the connector MPG.
Operation panel
I/O unit
MPG
(2) Connecting with 12V manual pulse generator (maximum cable length: 50m)
Connect the 12V manual pulse generator to the connector MPG.
Operation panel
I/O unit
MPG
(Note 1) When selecting a manual pulse generator, make sure that its case and 0V terminal are insulated.
(Note 2) Select 25pulse/rev or 100pulse/rev on the parameter screen.
<Related items>
Cable drawing: "Cable: F023/F024 Cable"
Connector pin assignment: "General Specifications: Operation Panel I/O Unit" (MPG connector)
: #1240 set12/bit0 = 0 ( 25 pulse/rev)
When connecting one 5V
manual pulse generator
F023 cable
When connecting two 5V
manual pulse generators
F024 cable
When connecting one
12V manual pulse
generator
F320 cable
When connecting two
12V manual pulse
generators
F321 cable
E70 Series Connection Manual
4.3 Connection of Operation Panel I/O Unit
NO.1
5V manual pulse
  5V 0V    A    B
generator
(Rear view)
NO.1
NO.2
  5V 0V    A    B
  5V 0V    A    B
NO.1
12V manual pulse
generator
12V 0V    A    B
HD60C (Rear view)
NO.1
NO.2
12V 0V    A    B
12V 0V    A    B