32 Setting the Deceleration Check

32.4 Parameter

(1) Designating deceleration check
Base specification parameter
#
Item
The definitions are changed with the setting of "#1306 InpsTyp
1193
inpos
Deceleration check specification type".
When
Deceleration
check method 1 is
selected
When
Deceleration
check method 2 is
selected
Deceleration
1223
aux07/bit1
check method 2
Deceleration
1306
InpsTyp
check
specification type
Smoothing check
1389
G1SmthChk
method in cutting
block
(2) Deceleration check during opposite direction travel
Base specification parameter
#
Item
G1 -> G0
1502
G0Ipfg
deceleration
check
G1 -> G1
1503
G1Ipfg
deceleration
check
IB-1501268-K
Details
Select the deceleration check method for G0.
0: Command deceleration check
1: In-position check
2: Smoothing check
Select the deceleration confirmation method for the
positioning or cutting command.
0: G0, G1+G9 Command deceleration check
1: G0, G1+G9 In-position check
2: G0,G1+G9 Smoothing check
Select the deceleration check method in G1+G9.
0: Command deceleration check in G1+G9
1: In-position check in G1+G9
The deceleration check is not performed for the
commands except G1+G9.
When "#1306 InpsTyp deceleration check
specification type" is set to "1" (Deceleration check
specification type 2), this parameter will be invalid.
Select the parameter specification type for the G0 or
G1 deceleration check.
0: Deceleration check specification type 1
G0 is specified with "#1193 inpos",
and G1+G9 with "#1223 aux07/bit1".
1: Deceleration check specification type 2
G0 or G1+G9 is specified with "#1193 inpos".
Select whether to apply smoothing check method to a
cutting block for deceleration check, when
deceleration check method is selected individually for
G0 and G1 (when #1306 InpsTyp=1).
0: Follow the setting of Aux07/BIT1
1: Apply smoothing check method
Details
Select whether to perform a deceleration check when the
travel direction is changed from G1 to G0.
0: Not perform
1: Perform
Select whether to perform a deceleration check when the
travel direction is changed from G1 to G1.
0: Not perform
1: Perform
568
Setting range
0 to 2
0 / 1
0 / 1
0 / 1
Setting range
0 / 1