M800W/M80W Series Connection and Setup Manual
4 General Specifications
4.2.2 Environment Conditions inside the Control Panel
Item
Ambient
temperature
Ambient
humidity
Vibration resistance
Shock resistance
Working atmosphere
General
Altitude
Specifications
Power supply voltage
Current consumption
Maximum
heating value
Mass
Outline
dimension
W×H×D
(Note 1) "Short term" means within one month.
(Note 2) For the whole NC system, consider the characteristics of the drive units when the altitude is more than 1000
meters above sea level. Refer to the manual of drive unit for details.
Unit name
Type
During operation
During storage
Long term
10 to 75% RH (with no dew condensation)
Short term
10 to 95% RH (with no dew condensation) (Note 1)
Operation/Storage: 1000 meters or less above sea level,
Transportation: 13000 meters or less above sea level
(W)
(kg)
(mm)
Control unit
FCU8-MU044
0 to 55°C
-20 to 60°C
2
4.9m/s
[0.5G] or less
2
29.4m/s
[3G] or less
No corrosive gases, dust or oil mist
24VDC
1.25A
16
2.0
60×380×180
29
IB-1501268-K