Mitsubishi Electric M800W Series Connection And Set Up Manual page 124

Hide thumbs Also See for M800W Series:
Table of Contents

Advertisement

M800W/M80W Series Connection and Setup Manual
4 General Specifications
(12) SIO (RS-232C communication 2ch)
10
20
1
0V
2
I
RD1(RXD1)
3
I
CS1(CTS1)
4
I
DR1(DSR1)
5
0V
6
NC
7
I
RD2(RXD2)
8
I
CS2(CTS2)
9
I
DR2(DSR2)
10
NC
- Connect connector case with FG pattern.
<Cable side connector type>
Plug : 10120-3000PE
Shell : 10320-52F0-008
Manufacturer: 3M
(Note)
1
11
11
0V
12
O
SD1(TXD1)
13
O
RS1(RTS1)
14
O
ER1(DTR1)
15
0V
16
NC
17
O
SD2(TXD2)
18
O
RS2(RTS2)
19
O
ER2(DTR2)
20
NC
When using the jackscrew M2.6-type 10320-52A0-008 for the shell, do not fasten the screws
too tightly otherwise the connector and the PCB may be damaged.
(Manufacturer recommended tightening torque: 0.20±0.05Nꞏm)