6 Precautions for Connecting

6.2 Turning the Power ON/OFF

(1) To turn the power ON
L1 L2 L3
(a)
No-fuse breaker
(NFB)
CP
AC power
supply
CP
AC power
supply
(b) 24VDC is input to the control unit and the
startup of the control unit starts.
The startup is temporarily stopped when RIO
communication gets ready.
The startup of control unit restarts.
Control unit servo ready (RDYON)
(c)
ON
G170
OFF
J070/J071
24VDC
(b)'
24VDC stabilized
power supply (2)
J070/J071
DCOUT
24VDC
ACIN
24VDC stabilized
power supply (1)
J070/J071
DCOUT
24VDC
ACIN
(b)
(a) The main breaker is turned ON and AC power is input
to stabilized power supplies (1) and (2).
NC control section startup is completed.
243
Personal computer unit
ON
OFF
DCIN
GDI
KEYUSB
J291
(d)
Operation panel
USB+S5+ON/OFF
I/O unit
KEYUSB
DCIN
RIO3
J210
(e)
Control unit
RIO2.0
RIO3
DCIN
GDI
(b)' 24VDC is input and the operation panel I/O starts up.
The personal computer unit waits for startup until the
ON switch is pressed.
(c) The startup of personal computer unit starts when the
ON switch is pressed.
(d) ON signal is notified to USB+S5+ON/OFF.
(e) ON signal is notified to RIO 2.0.
The startup of the personal computer unit is completed.
Startup completion signal (S5STATE) is notified to the
control unit through (d) and (e).