M800W/M80W Series Connection and Setup Manual
12 Connection of Remote I/O Unit

12.10 Connecting with Thermistor (FCU8-DX408)

Connect the thermistor with THERMISTOR connector.
The maximum cable length is 25m.
The recommended shield cable is "HK-SB/20276XL, black, LF 1P X 22AWG" made by Taiyo Cabletec.
Thermistor
<Related items>
Connector pin assignment: "General Specifications: Remote I/O Unit" (THERMISTOR connector)
Note
1. Connect the cable to the designated connector. Incorrect connections could damage the device.
2. Do not connect or disconnect the connection cables between each unit while the power is ON.
3. Use the cable with shield and ground it in order to reduce the influence of noise.
Cable with shield
Maximum: 25m
335
THERMISTOR