Synchronous Control Mode; Correction Mode - Mitsubishi Electric M800W Series Connection And Set Up Manual

Hide thumbs Also See for M800W Series:
Table of Contents

Advertisement

M800W/M80W Series Connection and Setup Manual
33 Synchronous Control and Multiple-axis Synchronization Control

33.1.1.1 Synchronous control mode

The following two operation methods are available in the synchronous control mode.
(1)
Synchronous operation
This is a method that both master and slave axes are moved simultaneously with the movement command for the
master axis.
(2) Independent operation
This is a method that either the master or slave axis is moved with the movement command for the master axis.

33.1.1.2 Correction mode

The synchronization is temporary canceled to adjust the balance of the master and slave axes during the synchronous
control mode in the machine adjustment. Each axis can be moved separately with the manual handle feed or the
arbitrary feed in manual mode. If the operation mode other than the manual handle feed and arbitrary feed in manual
mode is applied during the correction mode, the operation error will occur.
577
IB-1501268-K

Advertisement

Table of Contents
loading

This manual is also suitable for:

M80w seriesM850wM830wM80w

Table of Contents