Mitsubishi Electric M800W Series Connection And Set Up Manual page 83

Hide thumbs Also See for M800W Series:
Table of Contents

Advertisement

M800W/M80W Series Connection and Setup Manual
4 General Specifications
(21) DCIN (24VDC input)
1
1
I
+24V
2
0V
3
FG
<Cable side connector type>
Connector : 2-178288-3
Contact : 1-175218-5
Manufacturer: TE Connectivity
(a) Specifications of power supply
Consider the following characteristics when selecting the stabilized power supply (prepared by machine
tool builder). Use a power supply that complies with CE Marking or that follows the safety standards given
below.
[Stabilized power supply selection items]
Output Voltage fluctuation ±5% or less of 24VDC
Power capacity
Output holding time
Overcurrent protection
[Standards]
Safety Standards: UL1950, CSA C22.2 No. 234 approved, IEC950 compliant
Noise Terminal Voltage: FCC Class A, VCCI-Class A
High Harmonics Current Restrictions: IEC61000-3-2
(Note)
CAUTION
1. Using a stabilized power supply without overcurrent protection may cause the unit's failure due to miswiring of
24V.
(22) FG (FG terminal)
(23) SD (SD card I/F)
IB-1501268-K
3
Item
Ripple noise
200mV (P-P)
Calculate the current value as a reference of maximum current consumption for the
unit which uses the power supply.
20ms
Required
24VDC voltage may drop instantaneously due to rush current at the beginning of 24V power
supply to the control unit.
The level of voltage drop depends on the capacity of the power supply. Do not share the power
supply with the devices that have alarms to warn the voltage drop.
Standard setting