Mitsubishi Electric M800W Series Connection And Set Up Manual page 619

Hide thumbs Also See for M800W Series:
Table of Contents

Advertisement

M800W/M80W Series Connection and Setup Manual
33 Synchronous Control and Multiple-axis Synchronization Control
(2) Position alignment without using reference position adjustment value
[ When synchronization at zero point establishment (#1493 ref_syn) is "0" (asynchronous) ]
(a) Select the correction mode, and feed the master and slave axes using the manual handle to correct the error
between the two axes.
Use an instrument such as a level to detect horizontal level errors between the synchronous axes.
(b) Adjust the dog position.
Adjust the dog position so that the return position is always the same at reference position return.
(c)
Change back to synchronous mode, and carry out manual dog-type reference position return.
Make sure to decelerate enough before carrying out reference position return.
When the master and slave axes individually decelerate and reach zero point after the master axis' dog ON,
adjust each axis' reference position shift distance (#2027 G28sft) so that there is no error between the two
axes.
[ When synchronization at zero point establishment (#1493 ref_syn) is "1" (synchronous) ]
(a) Set "#2036 slv_adjust" (reference position adjustment value) to "0".
(b) From the PLC, turn ON the master and slave axis bits of the "synchronous control operation method" signal to
select "synchronous control mode" synchronous operation.
(c)
Carry out zero point return manually.
The master axis travels until reaching the second grid after dog OFF, and stops on the grid.
(If the deceleration after dog OFF goes over the 1st grid, the master axis stops on the 3rd grid)
The slave axis travels in synchronization with the master axis.
(d) When necessary, adjust the zero point using the reference position shift distance (#2027 G28sft).
Set the reference position shift distance to the master axis' parameter. If set to the slave axis' parameter, the
setting is ignored.
Position alignment after power ON
Normally, positions of the master and slave axes deviate at power ON, thus the position alignment for this deviation is
required.
This position alignment is automatically done at the first dog-type reference position return after power ON. However, the
settings of the zero point return parameters such as the reference position shift distance must be adjusted correctly.
Synchronous error check is not carried out until this position alignment is done.
Below is an example of reference position return.
Master axis
Slave axis
Grid
IB-1501268-K
(G28sft)
Master axis's
reference position
shift distance
Basic point
(G28sft)
Slave axis's
reference position
shift distance
Reference position
580

Advertisement

Table of Contents
loading

This manual is also suitable for:

M80w seriesM850wM830wM80w

Table of Contents