37 Data Backup and Restoration
The following two functions are available for the data backup and restoration: all backup function for files in batch and
input/output function for separate files.
The following devices are available in all backup and restoration.
HD (Hard disk (for Windows-based display unit only))
Memory card (Front-side SD card)
DS (Control unit-side SD card)
USB memory
The master data backup and restoration are used for backing up and restoring the initial state data set by MTB. The built-
in memory is used for the master data backup and restoration regardless of the selected device.
Files to be backed up/ restored are as follows.
Screen display
System data
Ladder
Safety parameter
Safety ladder1
Safety ladder2
APLC data
Custom data
(*1) These data can be backed up only, cannot be restored.
(*2) "XXX" indicates the abbreviation for each language.
For the input/output function for separate files, refer to the "Instruction Manual".
IB-1501268-K
File name
SRAM.BIN
ALL.PRM (*1)
ASSEMBLY.INF (*1)
USERPLC.LAD
EIPCONFDATA.BIN
PLCMSG_XXX.TXT (*2)
PLCUMSG_XXX.TXT (*2)
MCRMSG_XXX.TXT (*2)
SAFEPARA.BIN
SAFEPLC1.LAD
SAFEPLC2.LAD
APLC.BIN
-
Data type
SRAM data (binary files)
Programs, parameters, R registers and so on
Parameters
System configuration
User PLC program
EtherNet/IP configuration file
PLC message file for MTB
PLC message file for users
Macro alarm message file
Safety parameter (binary file)
Safety PLC program1
Safety PLC program2
C language module created by user
Custom screen data
(Custom screen modules, setting files (Config.ini/
customdef.ini/customload.txt) and PLC alarm messages)