M800W/M80W Series Connection and Setup Manual
17 Connection of Handy Terminal
This chapter briefly explains how to connect the handy terminal to each unit and device.
17.1 Handy Terminal Connection System Drawing
[M800W]
Handy terminal
HOST
[M80W]
Handy terminal
HOST
(Note)
When the handle of handy terminal is used on M80W, connect ENC connector of G430 cable to MPG
connector of the operation panel I/O unit.
Because the pin assignment of ENC connector of G430 is different from that of MPG connector of the
operation panel I/O unit, conversion is required. The conversion cable needs to be prepared by the MTB.
17.2 Connecting with Control Unit
Connect the handy terminal to SIO connector and AIO connector (M800W only) of the control unit.
Also, connect the emergency stop switch (SW1), enable switch (SW2), selector switch (SW) and 24VDC input to the
control panel terminal block.
[Example connection of M800W]
Control unit
SIO
SIO
AIO
AIO
Control panel
terminal block
IB-1501268-K
G430
cable
G430
cable
SIO
SIO
G430 cable
ENC
ENC
Control unit
SIO
AIO
Control unit
SIO
Handy terminal
Connector name: HOST
FG
FG
368