Mitsubishi Electric M800W Series Connection And Set Up Manual page 346

Hide thumbs Also See for M800W Series:
Table of Contents

Advertisement

M800W/M80W Series Connection and Setup Manual
11 Connection of Operation Panel I/O Unit
[FCU8-DX834]
Machine side
Stabilized
power supply
24VDC(+)
0V
FG
For connection details, refer to the descriptions on machine output connector pin assignment in "(2) Machine signal
output (CG32)" and "(4) Machine signal output (CG34)" of "General Specifications: Operation Panel I/O Unit".
FCU8-DX834
CG32
B20
Y200
B19
Y201
B18
Y202
B17
Y203
B16
Y204
B15
Y205
B14
Y206
B13
Y207
B12
Y208
B11
Y209
B10
Y20A
B09
Y20B
B08
Y20C
B07
Y20D
B06
Y20E
B05
Y20F
B04
+24V
B03
+24V
B02
+24V
B01
+24V
A20
Y210
A19
Y211
A18
Y212
A17
Y213
A16
Y214
A15
Y215
A14
Y216
A13
Y217
A12
Y218
A11
Y219
A10
Y21A
A09
Y21B
A08
Y21C
A07
Y21D
A06
Y21E
A05
Y21F
A04
+24V
A03
+24V
A02
0V
A01
0V
Stabilized
DCIN
power supply
1
+24V
24VDC(+)
2
0V
0V
3
FG
FG
307
Machine side
FCU8-DX834
CG34
B20
B19
B18
B17
B16
B15
B14
B13
B12
B11
B10
B09
B08
B07
B06
B05
B04
B03
B02
B01
A20
A19
A18
A17
A16
A15
A14
A13
A12
A11
A10
A09
A08
A07
A06
A05
A04
A03
A02
A01
DCIN
1
2
3
Y220
Y221
Y222
Y223
Y224
Y225
Y226
Y227
Y228
Y229
Y22A
Y22B
Y22C
Y22D
Y22E
Y22F
+24V
+24V
+24V
+24V
Y230
Y231
Y232
Y233
Y234
Y235
Y236
Y237
Y238
Y239
Y23A
Y23B
Y23C
Y23D
Y23E
Y23F
+24V
+24V
0V
0V
+24V
0V
FG
IB-1501268-K