39 Appx.2: Protection Setting

39.6 Changing the Protection Level

Changing the protection level is available only for the data being set in the lower level than a current operation level.
Operation Methods
(Example) Change the "Available level" from "4" to "5"
(1)
Press the menu [Setup pro lev].
(2)
Move the cursor to the protection level to be changed,
then enter the new protection level.
(Example) 5 [INPUT]
(3)
Press the menu [Setup pro lev].
(Note 1) When the value of "Available level" in the setup protection level is higher than the current operation level, the
protection level is unable to change. (The menu [Setup pro lev] is grayed out.)
(Note 2) The higher protection level than the current operation level is unable to set.
(When the current operation level is "5", the protection level is unable to be set to "6".)
(Note 3) When changing the protection level during input-output, an error may occur in the middle of the input-output.

39.7 Saving the Protection Level Setting

Operation Methods
(1)
Press the menu [Save pro lev].
(2)
Press the [Y] or [INPUT] key.
(Note 1) After changing the protection level, if the screen is switched without saving the change, the operation message
"Save the protective level setting? (Y/N)" is displayed. If you switch the screen without saving the change, the
changed setting is canceled.
(Note 2) After changing the protection level, if you turn the power OFF without saving the change, the changed protection
level is canceled.
IB-1501268-K
The menu [Setup pro lev] is highlighted.
The cursor appears on the "Chng" of "Available level".
"5" is set in the "Chng" field of "Available level".
The cursor moves to the right when "Chng" is set.
(The cursor moves downward when "Available level" is
changed.)
The cursor moves to the left below when [Out.] is set.
"Pro lev change" is displayed on the upper right of the screen.
The highlighted menu [Setup pro lev] turns to normal.
The cursor disappears.
The operation message "Save the protective level setting? (Y/
N)" is displayed.
The operation message "Protective level setting has been
saved." is displayed.
The displayed message "Pro lev change" on the upper right of
the screen is disappeared.