M800W/M80W Series Connection and Setup Manual
11 Connection of Operation Panel I/O Unit

11.3 Connecting with Emergency Stop Signal

Connect the emergency stop switch to EMG connector of the operation panel I/O unit.
Operation panel I/O unit
Operation panel I/O unit
R
EMGIN
LG
Emergency stop input circuit
<Related items>
Cable drawing: "Cable: J120 Cable"
Connector pin assignment: "General Specifications: Operation Panel I/O Unit" (EMG connector)
<When not using operation panel I/O unit side emergency stop input signal (EMG)>
When not using operation panel I/O unit side emergency stop input signal (EMG), such as when control unit side
emergency stop input signal (EMG) is used, invalidate the input signal by using terminal cable G123.
Note that G123 cable does not come with the operation panel I/O unit. (G123 cable comes with the control unit.)
Operation panel I/O unit
EMG
(Note)
When installing emergency stop switch at operation panel and electric cabinet each, both emergency
stop input signals (EMG), the signal at the operating panel I/O unit side and at the control unit side, can
be used.
IB-1501268-K
J120
EMG
+24V
FG
G123
Emergency
stop switch
Emergency
stop switch