Goodrive350-19 series VFD
Function
Name
code
2
Description
Output
frequency
P93.26
P93.28
Output
torque
P93.26
VFD
Normal
status
1: Mode 2. The VFD outputs the loose rope
protection alarm (A-SL), changes the direction,
and runs upward at the frequency specified by
P93.31, and the VFD runs downward only when
the time specified by P93.30 is reached or the
loose rope status disappears.
Output
frequency
P93.31
P93.26
Target
P93.28
frequency
Output
torque
P93.26
Normal
VFD
status
P93.30 setting range: 0–20.00s
P93.31 setting range: 1.00Hz–10.00Hz
- 385 -
Time t
Loose rope
protection
SLE
fault
Time t
P93.30
Loose rope
protection
A-SL alarm