Goodrive350-19 series VFD
Function
Name
code
AI3 input signal
P25.41
type
S-terminal power
signal selection (S
P25.42
terminal
extension card 2)
7.2.26 P26 Output functions of extension I/O card
Function
Name
code
Y2 output
P26.02
selection
Relay RO3 output
P26.04
selection
Relay RO4 output
P26.05
selection
Output terminal
P26.12
polarity of
extension card
Y2 switch-on
P26.15
delay
Y2 switch-off
P26.16
delay
Setting range of P25.30: 0.00V–P25.32
Setting range of P25.31: -300.0%–300.0%
Setting range of P25.32: P25.30–10.00V
Setting range of P25.33: -300.0%–300.0%
Setting range of P25.34: 0.000s–10.000s
Range: 0–1
0: Voltage type
1: Current type
–
0
1
0: DC (24–48VDC)
on I/O
1: AC (24–48VAC)
Same as P06.01
0x0000–0x7FF
RO10, RO9...RO3, HDO2,Y3, Y2 in sequence
The function codes define the corresponding delay
of the level variation from switch-on to switch-off.
Description
Description
- 340 -
Function parameter list
Default
Modify
value
○
0
◎
0
Default
Modify
value
○
0
○
0
○
0
○
0x000
○
0.000s
○
0.000s