INVT Goodrive350-19 Series Operation Manual page 350

Hide thumbs Also See for Goodrive350-19 Series:
Table of Contents

Advertisement

Goodrive350-19 series VFD
Function
Name
code
P28.03 Slave speed gain 0.0–500.0%
P28.04 Slave torque gain 0.0–500.0%
Speed/torque
mode switching
P28.05
frequency point of
master/slave
mode 2
P28.06 Number of slaves 0–15
Master/slave
P28.07
transmission unit
pulse ratio
Position
synchronization
P28.08
deviation
deadzone setting
Position
synchronization
P28.09
deviation
threshold
Position
synchronization
P28.10
regulator output
limit
Position
synchronization
P28.11
pulse count reset
method
Description
0: Follow the master to start
1: Determined by P00.01
Hundreds: Slave transmitting/master receiving
data enable
0: Enable
1: Disable
0.00–10.00Hz
0.00–100.00
0–50000
When the position difference is greater than
P28.08, correction on the slave is valid.
0–50000
When the position difference is greater than
P28.09, the master/slave position fault (ELS) is
reported.
0.0–100.0%
0–1
0: Automatic
During stop, the position synchronization pulse
count is automatically reset.
1: Terminal based
If
the
input
terminal
synchronization pulse count reset function, the
- 343 -
selects
the
position
Function parameter list
Default
Modify
value
100.0%
100.0%
5.00Hz
1
1.00
50
1000
5.0%
0

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Goodrive350-19 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents