Function
Name
code
Reference object
P00.08
of B frequency
command
Combination
P00.09
mode of setting
source
Set frequency via
P00.10
keypad
Acceleration
P00.11
time 1
Deceleration
P00.12
time 1
P00.13 Running direction
Description
15: Graded multi-step speed
0: Max. output frequency
1: A frequency command
0: A
1: B
2: (A+B)
3: (A-B)
4: Max. (A, B)
5: Min. (A, B)
When A and B frequency commands are set by
keypad, the value is the initial digital set value of
the VFD frequency.
Setting range: 0.00 Hz–P00.03 (Max. output
frequency)
Acceleration time
accelerating from 0Hz to Max. output frequency
(P00.03).
Deceleration time is the time needed from
decelerating from Max. output frequency (P00.03)
to 0Hz.
Goodrive350-19 series VFD defines four groups of
acceleration and deceleration time, which can be
selected via multi-function digital input terminals
(P05 group). The acceleration/deceleration time of
the VFD is the first group by default.
Setting range of P00.11 and P00.12: 0.0–3600.0s
0: Run in default direction
1: Run in reverse direction
2: Reverse running is prohibited
- 204 -
is
the time
needed
Function parameter list
Default
Modify
value
0
0
50.00Hz
for
Model
depended
Model
depended
0