3 SPECIFICATIONS

3 SPECIFICATIONS
This chapter provides information on the performance specifications, transmission
specifications, etc. of the Web server module.
For the general specifications of the Web server module, refer to the user's manual of
the CPU module.

3.1 Performance Specifications

This section shows the performance specifications of the Web server module.
(1) Transmission and Interface specifications
Item
10BASE-T/100BASE-TX
Interface ( 1)
Communication method
Flow control Full-duplex
Half-duplex
Data transmission speed
Transmission method
Number of cascaded stages
Maximum segment length
Supported function
RS-232
Interface
Communication method
Synchronization method
Transmission speed
Transmission distance
Start bit
Data format
Data bit
Stop bit
Parity check
Transmission control
Recommended cable
External wiring applicable connector
CompactFlash card
Supply power voltage
Supply power capacity
Size
Number of mountable cards
Number of occupied I/O points
Maximum number of writes for
Standard ROM (Flash ROM)
Clock
5V DC internal current consumption
External dimensions
Weight
3 - 1
10BASE-T
10Mbps
Cascade connection Maximum 4 stages
( 2)
100m (length between a hub and a node) ( 3)
Auto negotiation function (automatically recognizes 10BASE-T/100BASE-TX)
7/0.127 P HRV-SV outside diameter: 8.5mm or longer
(Oki Electric Cable Company, Limited Specify the number of pairs in .)
32 points/1 slot (I/O assignment: intelligent 32 points)
Maximum 100,000 times to one area (refer to REMARKS (1))
The clock data is obtained from a programmable controller CPU (in multiple CPU
system, CPU No.1) (every 60s) (Refer to Section 3.9)
98 (3.86 in.) (H)
1 Web server module recognizes 10BASE-T/100BASE-TX according to the external device.
For connection with the hub that does not have the auto negotiation function, set the hub
side to the half-duplex communication mode.
Specifications
Full-duplex/half-duplex
None (Does not support to the IEEE802.3x)
Back pressure congestion control
Base band
Cascade connection Maximum 2 stages
Compliance with RS-232 (D-sub 9 pin)
Full-duplex communication
Start-stop synchronization method
9600, 19200, 38400, 57600, 115200 bps
Maximum 15m
1
8
1
None
Flow control (RS/CS control) is available
9 pin D-sub (Male) fixing type
3.3V 5%
Maximum 150mA
TYPE I card
1
0.69A
27.4 (1.08 in.) (W)
0.17kg (0.37Ib.)
MELSEC-Q
100BASE-TX
100Mbps
( 2)
90 (3.54 in.) (D) [mm]
3 - 1
3