Tag Event Monitor Status Area 1 (Address: 10000 To 10447) - Mitsubishi Electric MELSEC Q Series User Manual

Programmabale web server module
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

3 SPECIFICATIONS
Address:

3.8.14 Tag event monitor status area 1 (Address: 10000 to 10447)

Address:
3 - 52
(3) CPU event monitor error data (Address: 3002)
(a)
This area stores the CPU event monitor error data.
(b)
The bit corresponding to the CPU event setting No. of a CPU event monitor
error turns on.
0: No CPU event monitor error occurred
1: CPU event monitor error occurred
b15
b14
b13
b12
3002
16
15
14
13
(c)
The following is observed when a CPU event monitor error occurs.
(Example) When an error occurs in CPU event monitor of the CPU event
setting No. 16
 CPU event monitor error (X13) turns on
 CPU event monitor error data area (address: 3002 (bit 15)) of
 The error code is stored into the CPU event monitor 16 error
(4) CPU event monitor 1 to 16 error code (Address: 3003 to 3018)
The error code that indicates the error status is stored into the corresponding
CPU event setting No. area.
Refer to Section 9.3 for the error code.
The status related to the tag event monitor function can be confirmed.
Refer to Section 6.5 for the tag event monitor function.
(1) Tag event setting data (Address: 10000 to 10015)
(a)
This area stores information on whether "Tag event setting" in the event
setting has been made or not.
(b)
The bit corresponding to the preset tag event setting No. turns on.
0: Not set
1: Set
b15
b14
b13
b12
10000
16
15
14
13
10001
32
31
30
29
10002
48
47
46
45
10003
64
63
62
61
10004
80
79
78
77
10005
96
95
94
93
10006
112
111
110
109
10007
128
127
126
125
10008
144
143
142
141
10009
160
159
158
157
10010
176
175
174
173
10011
192
191
190
189
10012
208
207
206
205
10013
224
223
222
221
10014
240
239
238
237
10015
256
255
254
253
b11
b10 b9
b8 b7
b6
12
11
10
9
8
7
the buffer memory turns on.
code area (address: 3018) of the buffer memory.
b11
b10 b9
b8 b7
b6
12
11
10
9
8
7
28
27
26
25
24
23
44
43
42
41
40
39
60
59
58
57
56
55
76
75
74
73
72
71
92
91
90
89
88
87
108
107
106
105
104
103
124
123
122
121
120
119
140
139
138
137
136
135
156
155
154
153
152
151
172
171
170
169
168
167
188
187
186
185
184
183
204
203
202
201
200
199
220
219
218
217
216
215
236
235
234
233
232
231
252
251
250
249
248
247
b5 b4 b3 b2 b1
b0
6
5
4
3
2
1
b5 b4 b3 b2 b1
b0
6
5
4
3
2
1
22
21
20
19
18
17
38
37
36
35
34
33
54
53
52
51
50
49
70
69
68
67
66
65
86
85
84
83
82
81
102
101
100
99
98
97
118
117
116
115
114
113
134
133
132
131
130
129
150
149
148
147
146
145
166
165
164
163
162
161
182
181
180
179
178
177
198
197
196
195
194
193
214
213
212
211
210
209
230
229
228
227
226
225
246
245
244
243
242
241
MELSEC-Q
3 - 52

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec qj71ws96

Table of Contents