8 DEDICATED INSTRUCTION
8.6 Z(P).LOG
Internal device
Setting
(System, User)
data
Bit
(S)
(D)
[Instruction
code]
Z.LOG
ZP.LOG
Setting data
Setting data
Head I/O signal of the module
"Un"/Un
(00 to FE: The first 2 digits when the I/O signal is represented in
3 digits)
(S)
Head number of the device that stores the control data
Head number of the bit device that will be turned on for one scan
when the instruction is normally completed.
(D)
(D) + 1 also turns on when the instruction is abnormally
completed.
The local devices and the file registers for individual programs do not work as the devices for the setting data.
8 - 19
A logging command is issued with this command. (A logging is triggered.)
Link direct device
File
register
Word
[Execution
condition]
Command
Command
1: If the originating station is a Basic model QCPU (function version B or later), or
Universal model QCPU, " " (double quotation) of the first argument can be omitted.
Description
Applicable device
Intelligent
function
J
\
module
Bit
Word
U
Z.LOG
ZP.LOG
Index
register
Zn
K, H
\G
"Un"
(S)
"Un"
(S)
Setting side( 1)
User
User, System
System
MELSEC-Q
Constant
Others
$
(D)
(D)
Data type
String/
BIN16bit
Device
name
Bit
8 - 19